In the steam lines of thermal and nuclear power plants, condensed steam is usually discharged from components such as steam traps, control valves, or restriction orifices through draining lines that join to a collector pipe that connects to the condenser.
The size of this collector is typically calculated by applying rules of thumb that can vary significantly depending on the reference used. One source may suggest using a cross section equal to the sum of the sections of the connecting lines, another source may suggest several times this sum, while yet another suggests limiting the fluid velocity to small values, such as 50 ft/sec or less.
The result is that there are very different designs. For example, a 10-inch-diameter collector may have two lines of 4 in. plus two lines of 6 in. connected to them, while another collector of 16-in.-diameter only has two 2-in. lines connected.
In order to optimize the design of these collectors, the following guide takes into account the capacity of each draining line, the pressure in the connecting point, and the equivalent length of the collector.
The condensate collected in the drip pots of the steam lines is saturated or sub-cooled water that flashes when passing through the component, which continues flashing along the drain line. If the pressure of the condensate at the component entrance is the saturation pressure (PS) and the resistance coefficient of the component plus the line is K, the critical pressure at the collector connection (PCR) may be calculated using the graphs in Figures 1 or 2.
The maximum draining capacity of the line is calculated applying the following equation for saturated water:
W / d2 = 280 CE [(PS – PCR) / (ve K)]0.5 ln PS
where:
W is the flow rate of each drain line (lb/hr),
d is the internal drain piping diameter of the selected line with the minimum PCR value (in.),
CE is the expansion coefficient of the saturated water,
PS is the saturation pressure at the entrance of the component (psia),
PCR is the critical pressure at the end of the pipes (psia),
ve is the specific volume to PS (ft3/lb), and
K is the resistance coefficient of the pipe.
This equation has been deduced by the author from a 1961 research paper titled “Adiabatic Flow of Flashing Liquids in Pipes” written by M. Sajben and published by the American Society of Mechanical Engineers in its Journal of Fluids Engineering.
The CE is obtained from Figure 3 for the intersection of K with the critical conditions line. Figure 3 is based on PS = 1,000 psia as a reference pressure and the equation allows using the CE value for whichever other pressure. The pressure drop (PS – PCR) is divided between the component and the downstream piping.
When each line that connects to the collector is defined, knowing its flow capacity (W), the connection pressure (PCR), the saturation pressure at the component entrance (PS), and the resistance coefficient (K), the collector may be designated following these steps.
First. Select the connecting line with the minimum value of PCR and calculate the total flow (WT) that must be drained for the collector to the condenser as the sum of the flows of all connecting lines. If there are two or more connecting lines that have the same minimum value of PCR, select the line that has the greatest flow. For the structural design of the collector, use the maximum value of PCR.
Second. Calculate an equivalent diameter of the selected line (Do) as:
Do = d (WT / W)0.5
This equivalent line will have the same resistance coefficient (K) as the selected line, and it should be designated Ko.
Third. Calculate the resistance coefficient of the collector (KC) with the following expression:
KC = 1 + f [(LC / D) + (60 x n)]
where:
f is the pipe friction factor,
LC is the straight length of the collector (in.),
D is the internal diameter of the pipe collector (in.), and
is the number of the connecting pipes to the collector.
The friction factor inside the collector (f) will correspond to turbulent flow, so it may be expressed by the equation:
f = 0.022 / D0.207
Note that the value of the resistance coefficient for the end of the collector is 1, and the equivalent length (L) divided by the equivalent drain pipe diameter (D) of each connection to the collector is 60, assuming them as standard tees with the flow through the branch.
Select a value for D greater than or equal to Do. Calculate KC using the equation shown earlier, and KL using the following equation:
KL = Ko (D / Do)4, and
K = KC + KL.
In Figure 1 or 2, obtain the value of PCR for K and PS. This PS is the saturation pressure of the selected line at the entrance of the component, and PCR is the critical pressure at the end of the collector.
https://www.powermag.com/how-to-design-the-collector-pipe-for-condensate-return-lines/