Flow-Accelerated Corrosion in Pipe Wall Downstream of Orifice for Water and Air-Water Bubble Flows--Part I
Posted on 8th Sep 2019
ABSTRACT
An orifice is used widely as a flow meter or a contraction device in pipeline systems in hydro-power plants, thermal power plants, and chemical plants because of its simple construction, high reliability, and low cost. However, it is well known that flow-accelerated corrosion (FAC) occurs on the pipe wall downstream of the orifice. Some of the authors have examined FAC through experimental and numerical analyses and have reported that one of the major governing parameters of FAC for single-phase water flow is the pressure fluctuation p’ on the pipe wall, and also that pipe wall thinning rate TR can be estimated by p’. In addition, they have presented the effects of the ori-fice geometry on p’ or TR, and have described a method for suppressing p’ or TR. In the present study, FAC for a two-phase air-water bubble flow is examined and compared with the single-phase water flow experimentally. Further, it is shown that because p’ is also considered a governing parameter of FAC for a two-phase air-water bubble flow, TR can be estimated using p’. It is also indicated that, by using a downstream pipe with a smaller diameter than that of the upstream pipe, p’ or TR can be suppressed.
Received 2 February 2016; accepted 21 June 2016; published 13 July 2016
1. Introduction
The flow-accelerated corrosion (FAC), liquid droplet impingement (LDI) corrosion, and cavitation erosion (C/E) occurring in the piping system of power plants, and chemical plants, are serious problems because they lead to damage in the piping system.
An orifice is used widely as a flow meter or contraction device in a piping system in various plants because of its simple construction, high reliability, and low cost. It is well known that FAC occurs in a pipe wall downstream of the orifice. In fact, the accident that took place in the power plants, etc. was caused by FAC damage in pipes [1] - [5] . Chexal [1] investigated the FAC in power plant. Dooley and Chexal [2] investigated the effect of water chemistry on FAC. Poulson [3] investigated complexities in predicting erosion corrosion in an elbow and after an orifice. At the Mihama nuclear power plant, Japan, the pipe wall (diameter D = 560 mm) downstream of the orifice with an area contraction ratio of CR = 0.36 was broken by FAC after 21 years of use under the following conditions: flow rate of water Qw = 100 ton/hour, mean velocity um ≈ 2.2 m/s, pressure p = 0.93 MPa, and temperature T ≈ 142˚C [4] [5] .
The FAC has been studied from the viewpoint of material science, electrochemistry, and fluid dynamics [1] - [17] . The mechanism of occurrence has also been examined by considering the relationship between mass transfer and flow velocity, but this has not been fully elucidated.
In addition, Yoneda, et al. [4] [5] and Shakouchi, et al. [11] [15] found that the wall thinning rate can be expressed by the turbulent kinetic energy near the pipe wall and the pressure fluctuation on the pipe wall downstream of the orifice, respectively. The pressure fluctuation exerts repeated variable force on the pipe wall.
It has been shown that there is a good correlation between the pipe wall thinning rate TR and the turbulent kinetic energy k near the pipe wall as shown in Sections 1.1 and 1.2 or the pressure fluctuation p’ on the pipe wall downstream of the orifice for single-phase, water flow.
In this study, the flow accelerated corrosion (FAC) in a pipe wall downstream of the orifice is examined phenomenologically. In particular, FAC for a two-phase air-water bubble flow is examined experimentally and compared with that of a single-phase water flow. Further, it is shown that because p’ is also considered a governing parameter of FAC for a two-phase air-water bubble flow [11] [15] , TR can be estimated using p’. It is also indicated that, by using a downstream pipe with a smaller diameter than that of the upstream pipe, p’ or TR can be suppressed.
1.1. Wall Thinning Rate, Turbulent Kinetic Energy and Wall Shearing Rate for Water Flow
Figure 1 shows the variation of wall thinning rate distribution TR [mm/year] on the pipe downstream if the orifice and turbulent kinetic energy distribution k[m2/s2] at location 0.2D (D = 100 mm) separated from the pipe wall, as measured in earlier experiments for the Pipe line A and B of the Mihama nuclear power plant [4] [5] . Yoneda and Morita [4] [5] mentioned that TR depends on k near the pipe wall and Utanohara et al. [9] concluded that TR depends on the wall shearing stress, τ.
1.2. Relation between Wall Thinning Rate and Turbulent Kinetic Energy for Water Flow
Figure 2 shows the relation between TR and k derived from Figure 1 [16] . The TR is well approximated by the following linear function k, where the correlation coefficient R of the pipe-lines A and B are 0.97 and 0.95, respectively.
Phenomenologically, the TR can be well correlated with k [4] [5] which means TR can be decreased by decreasing k. However, because the measurement of k and τ is very complicated, some of the authors suggest that k and τ are conceptually related with pressure fluctuation p’ on the pipe wall [11] [15] [18] - [20] , which is then related with TR. Thus the TR can be estimated by p’ [11] [15] .
2. Experimental Apparatus and Procedure
Figure 3 shows the schematic diagram of the experimental apparatus. A submersible pump ② was used to send the required amount of tap water through an electromagnetic flow meter (Hitachi High-Tech Control Systems Co., Ltd., FMR104W) ⑤ into the pipe test section with diameter of D = 40.0 mm. The pipe test section was made of transparent acrylic resin with total length of L = 2650 mm and was set vertical. The air from the compressor ⑧ is mixed into the water flow by passing through the bubble generator ⑩ made of porous fine ceramics set at the bottom of the test section. The flow rate of air was measured and controlled by flow meter ⑨ and control valves. As a result, the flow becomes a two-phase gas-liquid bubble flow and after flowing in the test section only the water flows back to the water tank ①. The water in the tank was continuously renewed in order to maintain the water at a constant temperature. An orifice ⑦ was set at 40D downstream of the inlet of the test section.
The mean and fluctuating pressure distributions on the pipe wall up-stream and down-stream of the orifice were measured by small pressure holes (diameter of 0.8 mm), a water column manometer, and a semi-conductor type small pressure transducer (JTEKT, PD104SW-100K). The related pressure and primary resonance frequency of the transducer is 100 kPa and more than 6 kHz, respectively. The measurement time of the pressure fluctuation p’ was 2.5 s, and the sampling frequency was 1.0 kHz, and the mean value of 10 measurements was used. The dominant frequency of p’ was approximately 6 ~ 8 Hz in the present study.
Figure 4(a) shows a standard orifice (according to JIS Z8762, hereafter referred to as “Std”). The contraction area ratio CR of the orifice was 0.36. The inner diameters of the nozzle and the pipe were constant at d = 24.0 mm and D = 40.0 mm, respectively. The plate thickness was t = 4.0 mm, and the clearance angle of the outflow was constant at 45˚. Another Std-rev orifice which reversed the direction of the Std orifice was also used to reduce flow fluctuation downstream of the orifice.
Figure 1. Wall thinning rate TR [mm/year] and turbulent kinetic energy k [m2/s2] distribution [4] [5] .
Figure 2. Wall thinning rate TR vs. Turbulent kinetic energy k [16] .
Figure 3. Schematic diagram of experimental apparatus.
Figure 4. Test orifice.
Furthermore, one more Std nozzle with downstream pipe diameter of Dp < D = 40.0 mm was used with reference Std-Dp orifice as shown in Figure 4(b). This aims to suppress p’ or TR.
3. Results and Discussions
3.1. Flow Rate Coefficient of Orifice and Pressure Fluctuation for Single Phase (Water) Flow
3.1.1. Flow Characteristics of Orifice and Flow Rate Coefficient
In order to use an orifice as a flow meter or a contraction it is needed to make clear the flow characteristics of the orifice. In this section, the flow characteristics of orifice of Std, Std-rev and Std-Dp (Dp = 35.2 mm so that CR = 0.36) are examined in terms of flow rate coefficient.
The flow rate coefficient, C, of an orifice is defined by
(3)
where, A0 is the cross-sectional area of orifice hole, Q is the volumetric flow rate, and (p1 − p2) is the flow resistance of the orifice.
Figure 5 shows the flow rate coefficient, C, of the test orifice with area contraction ratio of CR = 0.36. The flow resistance (p1 − p2) of the orifice was obtained as the pressure difference derived from the linear pressure distributions following the Blasius relation [16] at upstream and downstream of the orifice. The flow rate coefficient of the standard orifice, Std, is C = 0.687, which is constant in Re = (1.0 ~ 6.5) × 104. This was consistent with the standard value and error range of less than ±0.5% provided by the JIS.
The pressure fluctuation, p’, of the Std-rev orifice is smaller than that of Std one because the inflow is smoother. Nevertheless, C is larger than in Std orifice and the flow resistance becomes smaller. This means that to measure the same flow rate with the same accuracy, a more accurate measurement of the flow resistance (p1 − p2) is needed.
3.1.2. Pressure Fluctuation
Figure 6 shows an example of the pressure fluctuation, p’, on the pipe wall downstream of the Std and Std-rev orifices. The CR is 0.36 and Re number is 5 × 104. The p’ of Std increases with downstream distance and takes the maximum value p’max around y/D ≈ 1.6. The p’max of Std-rev is about 9% smaller than that of Std and the y position of p’max shifts to y/D ≈ 2.0.
Figure 7 shows the time variation of pressure on the pipe wall at y/D = 1, 2, 3, and 4. The pressure at each position fluctuates with time and the amplitude at y/D = 2.0 is the largest in this case.
Figure 8 shows the relation between power spectrum density, PSD, and fluctuation frequency f of the pres-
Figure 5. Flow rate coefficient, C (CR = 0.36).
Figure 6. Pressure fluctuation p’ of Std and Std-rev (CR = 3.6, Re = 5.0 × 104).
Figure 7. Time variation of pressure p of Std.
Figure 8. FFT analysis of p.
sure fluctuation obtained by FFT analysis. The dominant frequency is observed 5 Hz and the y position of the maximum PSD is at y/D = 2.0.
As mentioned earlier, the profile of p’ of Std orifice is consistent with that of the wall thinning rate, TR. Figure 9 shows their relation in which their correlation factors of Pipe-lines A and B were 0.87 and 0.85, respectively. Since it can be said that there is a strong correlation between the TR and p’ the TR can be estimated by p’. The maximum pressure fluctuation of the Std-rev orifice is about 9% smaller than that of the Std orifice and the TR can be decreased.
Figure 10 shows one example of the variation of p’ of Std-Dp with downstream pipe diameter Dp [11] . In this figure, the curve at Dp = 40.0 mm is equivalent to the Std orifice. The overall value of p’ becomes smaller and decreases the Dp from 40.0 to 35.2 mm. It is therefore considered that the confinement of the flow by a smaller pipe diameter downstream of the orifice promote the decrease in the pressure fluctuation.
Figure 11 shows the relation between and Dp of the Std-Dp orifice. Accordingly, the maximum pressure fluctuation can be approximated by using polynomial function of Dp.
(4)
The decreases with a reduction in Dp, and the of Std-Dp orifice at Dp = 35.2 mm decreases with Dp = 35.2 mm, decreases approximately 16% of the Std orifice. That is, this Std-Dp orifice can decrease p’ or under the same flow resistance as the Std orifice. This means that Std-Dp can decrease FAC or wall thinning downstream of the orifice maintaining the functionality of the orifice.
3.2. FAC for Two-Phase Gas-Liquid (Air-Water) Bubble Flow
3.2.1. Flow Pattern and Bubble Size
Figure 12 shows an example of the visualized flow pattern of bubbles; the white spherical spots represent the air bubbles. The mean bubble size db was measured from the visualized flow pattern by using image processing software. The flow pattern was visualized by laser light sheet (laser light source; Ar, 3W), and its photograph was taken by a high-speed video camera (Nikon, D70kit). Parameter db is calculated as an equivalent-diameter circle using the total area of bubbles in the photograph and the number of bubbles. When the bubbles were overlapped in the photograph, db is obtained as the value of the maximum and minimum diameter of the bubble, measured using a ruler. The db values upstream of the orifice with CR = 0.36 at y/D = −3.75 ~ −2.5 for α = 2.5%, 5.0%, and 10.0% at Re = 1.0 × 104 were 2.37, 2.23, and 2.78 mm, respectively, and those downstream at y/d =
Figure 9. Wall thinning rate TR and pressure fluctuation p’.
Figure 10. Pressure fluctuation p’ of Std and Std-Dp [11] .
Figure 11. Maximum pressure fluctuation.
Figure 12. Visualized flow pattern of Std (CR = 0.36, Re = 1.0 × 104).
2.0 ~ 12.5 were 2.6, 2.9, and 2.8 mm, respectively. Here, α [= Qa/(Qa + Qw)] is the volumetric flow-rate ratio of air to mixture flow, i.e., the apparent void fraction. In all cases, the bubble size appears smaller after the passing of the bubble through the orifice, because of shearing force generated by the orifice. The bubble diameter decreased with increasing Re; for example, at Re = 5.0 × 104, the above-mentioned bubble diameters of 2.6, 2.9, and 2.8 mm decreased to 2.27, 2.31, and 2.5 mm, respectively.
3.2.2. Flow Resistance
The flow resistance, i.e., p1 − p2, for the two-phase air-water flow was measured in a manner similar to that for the single-phase water flow, and the pressure loss coefficient Cp = 2(p1 − p2)/(ρum2) was obtained. The Cp values of the Std orifice for α = 0%, 2.5%, 5.0%, and 10.0% were 9.9, 10.0, 10.1, and 10.3, respectively, whereas, those of the Std-Dp orifice with Dp = 38.2 mm were 8.1, 8.7, 8.9, and 9.1, respectively. The Cp values of the Std-Dp orifice with Dp = 38.2 mm for α = 0.0 and 10.0% were about 6.1% and 2.0% lower, respectively, than those of the Std orifice.